View products by country
Germany Spain Italy United Kingdom United States   View all countries

Renewable Energy Inverters - All Countries

Solar and Wind Inverters
 

Optimize Small-Wind-Turbine Energy Harvesting
With Aurora® Wind Inverters

Aurora® Wind Inverters utilize high-speed Maximum Power Point Tracking (MPPT) to increase the amount of energy that can be harvested from small wind turbines. These power curves use an algorithm for optimizing, via software, to match the output of a specific wind turbine.

Aurora® Wind Interfaces eliminate the need for any additional rectification. This simplifies and streamlines the installation to end users.

Industry-Leading Features and Performance

  • Aurora® Wind Inverter efficiencies exceed 97%.
  • Aurora® Wind Inverters provide less than 1% total harmonic distortion.
  • Aurora® Wind Interfaces deliver over 99% efficiency.
  • Aurora® Wind Interfaces provide automatic brake functions above 530 VDC with a user-supplied braking resistor.
Aurora® wind power inverters

Unmatched Applications Flexibility

  • Wind interfaces provide the capability to optimize the inverter’s power curve to the specific output characteristics of the wind turbine being used.

Installer Friendly

  • True sine-wave outputs feature self-selecting voltage capabilities.
  • Optional remote monitoring via the Internet.

Field-Proven Reliability

  • Rugged designs provide a 25-year MTBF while delivering full-rated power on a continuous basis.
  • Grid-connected operation approved to UL1741and international standards.

Click on the part numbers below to view a list of certifications and installation instructions

Country AC Power Part Number Data Sheet Additional Information
7.2kW PVI-7200-Wind-Interface-GI Download data sheet pdf  
4.0kW PVI-4000-Wind-Interface-GI Download data sheet pdf  
France 7.2kW PVI-7200-Wind-Interface-FR Download data sheet pdf Conditions a wind-turbine input for use with an inverter.
6.0kW PVI-6000-OUTD-FR-W Download data sheet pdf  
3.0 to 4.2kW PVI-3.0/3.6/4.2-OUTD-FR-W Download data sheet pdf  
4.0kW PVI-4000-Wind-Interface-FR Download data sheet pdf Conditions a wind-turbine input for use with an inverter.
Germany 7.2kW PVI-7200-Wind-Interface-DE Download data sheet pdf Aufbereitung der Einspeisung einer Windturbine für die Verwendung mit einem Wechselrichter.
6.0kW PVI-6000-OUTD-DE-W Download data sheet pdf Wirkungsgrade von bis zu 97% (96,5% Euro, 96,5% CEC).
3.0 to 4.2kW PVI-3.0/3.6/4.2-OUTD-DE-W Efficiencies up to 96.8% (96% CEC).
4.0kW PVI-4000-Wind-Interface-DE Download data sheet pdf Aufbereitung der Einspeisung einer Windturbine für die Verwendung mit einem Wechselrichter.
3.6kW PVI-3600-OUTD-DE-F-W Download data sheet pdf Eingebauter Kühllüfter.
Italy 7.2kW PVI-7200-Wind-Interface-IT Download data sheet pdf Condiziona l’ingresso di una turbina eolica da usare con un inverter.
6.0kW PVI-6000-OUTD-IT-W Download data sheet pdf Efficienze fino a 97% (96,5% Euro, 96,5% CEC).
3.0 to 4.2kW PVI-3.0/3.6/4.2-OUTD-IT-W Download data sheet pdf  
4.0kW PVI-4000-Wind-Interface-IT Download data sheet pdf Condiziona l’ingresso di una turbina eolica da usare con un inverter.
3.6kW PVI-3600-OUTD-IT-F-W Download data sheet pdf Raffreddamento con ventilazione interna.
Spain 7.2kW PVI-7200-Wind-Interface-ES Download data sheet pdf Condiciona la entrada de una turbina de viento para su uso con un inversor.
6.0kW PVI-6000-OUTD-ES-W Download data sheet pdf Eficiencias de hasta 97% (96,5% Euro, 96,5% CEC).
3.0 to 4.2kW PVI-3.0/3.6/4.2-OUTD-ES-W Download data sheet pdf  
4.0kW PVI-4000-Wind-Interface-ES Download data sheet pdf Condiciona la entrada de una turbina de viento para su uso con un inversor.
3.6kW PVI-3600-OUTD-ES-F-W Download data sheet pdf Enfriamiento mediante ventilador interno.
United Kingdom 6.0kW PVI-6000-OUTD-UK-W Download data sheet pdf Efficiencies up to 97% (96.5% Euro, 96.5% CEC).
3.0 to 4.2kW PVI-3.0/3.6/4.2-OUTD-UK-W Download data sheet pdf Efficiencies up to 96.8% (96% CEC).
3.6kW PVI-3600-OUTD-UK-F-W Download data sheet pdf Internal fan cooling.
United States 7.2kW PVI-7200-Wind-Interface-US Download data sheet pdf Conditions a wind-turbine input for use with an inverter.
6.0kW PVI-6000-OUTD-US-W Download data sheet pdf Efficiencies up to 97% (96.5% Euro, 96.5% CEC).
3.0 to 4.2kW PVI-3.0/3.6/4.2-OUTD-US-W Download data sheet pdf Efficiencies up to 96.8% (96% CEC).
4.0kW PVI-4000-Wind-Interface-US Download data sheet pdf Conditions a wind-turbine input for use with an inverter.

Admin | Resources | Universal Access | PATs | Z-Alliance | Search Logic
© 2007 Power-One Copyright and Disclaimer

All information listed on this web site, to the best of Power-One's knowledge, was timely and accurate when written. Please note that you should not rely on the continued accuracy of any material beyond the date of issuance since the passage of time can render such information stale. All viewers should carefully check the dates of issuance of the material contained on this web site.

Web Site Design & Programming by TSI